IBM Storage FlashSystem 9600
IBM FlashSystem 9600: an all-flash NVMe array in a 2U enclosure with IBM FlashCore Modules and IBM Storage Virtualize software.

Key Features
- 2U enclosure with 32 slots for NVMe drives in the EDSFF form factor
- IBM FlashCore Modules with hardware compression and deduplication
- Active-Active architecture with two node canisters
- Scale-out and workload mobility with the FlashSystem grid architecture
- Immutable volume groups and Safeguarded snapshots
Table of Contents
What is IBM FlashSystem 9600?
IBM Storage FlashSystem 9600 (model 5078-A40) is an NVMe storage array in a 2U enclosure that, according to IBM, supports up to 32 drives and is designed for the most demanding enterprise and AI workloads.
IBM announced FlashSystem 9600 on 10 February 2026, with a planned availability date of 6 March 2026 (later in some countries).
The array runs IBM Storage Virtualize software and uses IBM FlashCore Modules, performing compression, deduplication and encryption inline.
FlashSystem 9600 replaces FlashSystem 9500 in the IBM portfolio; IBM withdrew the 9500 from marketing effective 30 June 2026 — see the section below for details.
How does it work?
IBM Storage Virtualize
According to IBM documentation, IBM Storage Virtualize software provides the hosts attached to the array with functions including:
- a single pool of storage and logical unit virtualization,
- simple management of logical volumes,
- workload mobility and scale-out performance and capacity with the FlashSystem grid architecture,
- Distributed RAID providing redundancy and fast rebuild,
- a large, scalable cache,
- management and automation consistent across the Storage Virtualize portfolio: REST API, Ansible Playbooks, CSI and VMware integration, and a graphical user interface.
IBM FlashCore Modules
FlashSystem 9600 supports IBM FlashCore Modules with inbuilt hardware data reduction and computational storage assists; the system also supports industry-standard flash drives.
According to IBM, compression and deduplication are always on and performed in hardware on the FCM drives, with no impact on performance.
According to IBM, FlashCore Module 5 (FCM5) continuously monitors data from every I/O, and ransomware threat detection uses the computational storage assists of the modules.
IBM lists FCM capacities of 6.6, 13.2, 26.4, 52.8 and 105.6 TB for FlashSystem 9600.
Active-Active architecture
FlashSystem 9600 uses an Active-Active architecture: the two node canisters form a redundant I/O group, so a volume remains available if one canister fails or is taken offline.
The 2U control enclosure holds 32 slots for NVMe drives in the EDSFF form factor, two node canisters and two power supplies.
FlashSystem grid
According to IBM, FlashSystem grid enables non-disruptive scale-out, workload mobility and resource sharing across clusters.
For a grid of FlashSystem 9600 systems, IBM lists up to 377 PBe of effective capacity, up to 1,024 I/O ports and up to 2,752 GB/s of read bandwidth.
Data protection and cyber resilience
IBM documentation lists orchestrated immutable volume groups and Safeguarded snapshots among the Storage Virtualize functions.
IBM describes Policy-Based Replication (PBR) as a way to streamline disaster recovery with consistent, automated replication policies.
According to IBM, Policy-Based High Availability (PBHA) provides active-active access to critical workloads across two sites.
On the product page, IBM describes network-based replication across 3 sites designed to prevent a single point of failure.
IBM delivers real-time ransomware detection and proactive optimization through IBM Storage Insights; according to IBM, FCM technology inspects every I/O at the hardware level, enabling early detection of anomalies that may indicate ransomware.
According to IBM, encryption of data at rest is standard.
Specifications (per IBM)
Performance and capacity values in the table are maximums (“up to”) published by IBM for a single 2U enclosure; effective capacity (PBe) is IBM’s term, listed next to raw capacity.
| Parameter | Value |
|---|---|
| Model | 5078-A40 |
| Enclosure | 2U, up to 32 NVMe drives (EDSFF) |
| Raw capacity per enclosure | up to 3.37 PB |
| Effective capacity per enclosure | up to 11.8 PBe |
| Bandwidth (read) | up to 86 GB/s |
| IOPS (4K read hit) | up to 6.3 million |
| Response time (read) | under 50 µs |
| I/O ports | up to 32 |
| Cache | 1.5 TiB or 3 TiB |
| Fibre Channel | quad-port 64 Gb/s and 32 Gb/s adapters (SCSI, FC-NVMe) |
| Ethernet | dual-port 100 Gb/s and quad-port 25 Gb/s adapters (iSCSI or NVMe/TCP, replication) |
| Management | two 10 Gb/s Ethernet ports per node canister |
| FlashCore Modules | 6.6, 13.2, 26.4, 52.8 and 105.6 TB |
| FlashSystem grid | up to 377 PBe effective capacity, up to 1,024 I/O ports, up to 2,752 GB/s (read) |
FlashSystem 9600 and the withdrawn FlashSystem 9500
IBM withdrew FlashSystem 9500 arrays (models 4666-AH8 and 4983-AH8) from marketing and named IBM Storage FlashSystem 9600 (5078-A40) as the replacement product. IBM originally announced the withdrawal for 30 September 2026 and later moved the date to 30 June 2026; the withdrawal does not apply in India. FlashSystem 9500 had been available since March 2022, and according to the IBM product lifecycle page it can no longer be ordered as of 30 June 2026.
Use cases
IBM positions FlashSystem 9600 for consolidated mixed and critical OLTP workloads.
On the product page, IBM describes it as a solution for large, mixed and consolidated workloads, and in the announcement as a system for large-scale data centers and hybrid cloud infrastructures.
Scenarios IBM lists on the product page include:
- energy-efficient, dense data storage (storage sustainability),
- a data center with AI-driven data tiering (lights out data center),
- recovering data quickly and without interruption after a cyberattack,
- faster analytics of the data stored on the array.
Who is it for?
- Organizations that consolidate mixed workloads and critical OLTP databases on a single array.
- Mission-critical environments where, as IBM puts it, downtime is not an option.
- Companies that need replication and high availability across sites (PBR, PBHA).
- Teams planning to scale capacity and performance with the FlashSystem grid architecture.
How nFlo helps you deploy IBM FlashSystem 9600
We help you choose the array configuration — modules, adapters and cache — for your workloads, design the storage and cross-site replication architecture, deploy the system and migrate data from your current array, including earlier-generation systems from the IBM FlashSystem family.
We integrate the array with your server environment, virtualization and backup systems as part of our storage implementation services.
We resell vendor support and provide our own support on terms set in the contract — scope and response times (SLA) are agreed individually.
Contact us to discuss sizing and deploying this array.
FAQ
Does FlashSystem 9600 replace FlashSystem 9500?
Yes. In the FlashSystem 9500 withdrawal announcement, IBM named IBM Storage FlashSystem 9600 (5078-A40) as the replacement product; IBM ultimately set the 9500 withdrawal date to 30 June 2026.
Which protocols does FlashSystem 9600 support?
According to IBM documentation, the 64 Gb/s and 32 Gb/s Fibre Channel adapters support SCSI and FC-NVMe, while the 100 Gb/s and 25 Gb/s Ethernet adapters support iSCSI and NVMe/TCP for host I/O, as well as replication.
What is FlashSystem grid?
It is an IBM Storage Virtualize capability that, according to IBM, enables non-disruptive scale-out, workload mobility and resource sharing across clusters; for a grid of 9600 systems, IBM lists up to 377 PBe of effective capacity.
How does FlashSystem 9600 protect data against ransomware?
According to IBM, FCM technology inspects every I/O at the hardware level, IBM Storage Insights detects ransomware and anomalies in real time, and Storage Virtualize provides immutable volume groups and Safeguarded snapshots.
What does support look like?
According to IBM documentation, FlashSystem 9600 is available with IBM Storage Expert Care, with several levels of support. nFlo resells vendor support and provides its own support on terms set in the contract.
Inquire about IBM Storage FlashSystem 9600
Contact your product specialist and get a custom quote.

Related Services
Our services supporting the implementation and management of this solution
Comprehensive IBM i (AS/400) Services
IT Infrastructure
Maintain IBM i system stability without costly migration. Administration and modernization from specialists with 20+ years experience.
Comprehensive Storage Services
IT Infrastructure
Build storage that won't fail at critical moment. Design, implementation, support from storage specialists.
IBM Power Services
IT Infrastructure
Maintain critical IBM Power systems: administration, migrations and high availability. Specialists with 20+ years of market experience.
Storage System Implementation
IT Infrastructure
Fast storage with enterprise redundancy. Performance matched to workloads, not budget.
From Our Knowledge Base
Articles related to this solution
CVE-2026-107331: Path Traversal in IBM DataStage on Cloud Pak for Data 5.4
Security Alert - CVE-2026-107331 (IBM DataStage on Cloud Pak for Data 5.4.0.0). CVSS: 9.9 (critical). Absolute path traversal by an authenticated attacker; fixed in 5.4 patch 8.
CVE-2026-123218: Authorization Bypass to Admin in IBM Aspera Faspex
Security Alert - CVE-2026-123218 (IBM Aspera Faspex 5.0.0–5.0.19). CVSS: 9.8 (critical). Authorization bypass grants full administrative privileges; fixed in 5.0.19 PL1.
IBM API Connect: 47 Critical Vulnerabilities (CVE-2026-17360 and Others) — RCE, SQLi, Auth Bypass
Security Alert - CVE-2026-17360 and 46 other CVEs in IBM API Connect 10.0.8.0–10.0.8.12 and 12.1.0.0–12.1.1.2. CVSS: 9.0–9.9 (critical). Fixes: 10.0.8.13 and 12.1.1.3.
Related Products
Other solutions you might be interested in
Dell PowerScale
Dell Technologies
Dell PowerScale (Isilon): scale-out NAS for petabytes. NFS, SMB, S3. Analytics, media, AI/ML datasets. OneFS single namespace.
Dell PowerStore
Dell Technologies
Dell PowerStore: next-gen all-flash storage. NVMe, AppsON (containers on array), intelligent automation. Block, file, vVols.
IBM Apptio
IBM
IBM Apptio: FinOps and IT cost management platform. Shows how much you spend on IT/cloud, who pays for what, where to save. Cloudability for AWS/Azure/GCP optimization.
IBM Cloud Pak for AIOps
IBM
IBM Cloud Pak for AIOps: AI-driven IT operations. Alert correlation into incidents, predictive detection, automated remediation, multi-cloud visibility.
Want to Reduce IT Risk and Costs?
Book a consultation - we respond within 24h
Or download free guide:
E-book: Digital Resilience Strategy 2026