OT/ICS Ransomware Resilience Testing
83% of ransomware attacks hit industry through IT, but stop production. We'll prepare your OT environment for attack - segmentation, critical system backup, recovery procedures. Even if IT goes down, production keeps running.
Describe your scope — your account manager will reply within 24 hours.
- Custom quote

What is OT/ICS Ransomware Resilience Testing?
OT/ICS Ransomware Resilience Testing analyzes how ransomware could propagate from the corporate IT network into the OT environment, verifies the effectiveness of IT/OT segmentation, and tests whether SCADA, HMI, and PLC backups can actually restore production — all in controlled conditions with no risk to live systems. nFlo delivers a risk map, verified recovery procedures, and a step-by-step attack playbook, directly addressing NIS2 requirements for critical infrastructure business continuity; 83% of industrial ransomware attacks enter through IT.
Contact your account manager
Discuss OT/ICS Ransomware Resilience Testing with your dedicated account manager.

Ransomware in IT stops production - costs millions
Comprehensive OT ransomware resilience
IT/OT Segmentation
Isolate production environment from IT
System Backup
Secure critical configurations and data
Recovery Plan
Recovery procedures tested in practice
Colonial Pipeline - 5 Days Downtime, $4.4M Ransom
In May 2021 DarkSide ransomware attack paralyzed the largest fuel pipeline in USA. Attackers got in through IT, but company shut down all OT “for safety”. Result? 5 days downtime, state of emergency, $4.4 million ransom.
Without ransomware preparation in OT:
- Production downtime even when attack only affected IT (“just in case” principle)
- Financial losses - every hour of downtime costs hundreds of thousands
- No certainty whether production can safely resume
- Penalties for service unavailability (critical infrastructure)
- Reputation and customer trust loss
Preparation for Worst Case Scenario
We don’t wait for ransomware to reach OT. We prepare industrial environment so that even if IT gets blocked, production can operate safely.
What you get:
- Risk analysis of ransomware spread from IT to OT
- Attack simulation in controlled conditions (no production risk)
- Verification of IT/OT network segmentation effectiveness
- SCADA, HMI, PLC backup and recovery procedure testing
- Air-gap assessment for critical systems
- Prioritized remediation action plan
- Post-attack recovery procedures (playbook)
- Team training on recovery procedures
Test Scenarios and Tooling
Every OT/ICS ransomware resilience test is based on real-world attack scenarios observed in industrial environments. We don’t simulate abstract threats - we replicate tactics and techniques used by groups like LockBit, BlackCat, and ALPHV in attacks on manufacturing and critical infrastructure.
Lateral movement simulation verifies whether ransomware that infected a workstation on the corporate network can reach the OT zone. We test pathways through jump hosts, vendor VPNs, shared storage, and inter-VLAN links. We evaluate the effectiveness of industrial firewalls, microsegmentation rules, and NAC (Network Access Control) policies in blocking lateral traffic.
Backup integrity testing goes beyond verifying that backups exist. We actually restore PLC configurations from backups, load HMI images, and recover SCADA databases on a test environment. We measure actual RTO (Recovery Time Objective) and RPO (Recovery Point Objective) for each critical OT component. We also verify whether backups are protected by air-gap or immutable storage against ransomware encryption.
Response playbook is the key deliverable - a document describing step-by-step actions upon ransomware detection: who makes the decision to isolate OT, how to safely disconnect systems from IT without halting critical processes, communication procedures with CERT and regulators, and conditions for safely resuming production after an incident.
Who Is It For?
This service is for you if:
- You run 24/7 production and every hour of downtime means huge losses
- You’re critical infrastructure operator (energy, water, transport, chemical industry)
- You have connection between corporate network and OT
- You want to meet NIS2 ransomware resilience requirements
- You see ransomware attacks on other companies in your industry and want to prepare
Testing Methodology
Safety First
Ransomware testing in OT requires special caution. We use approach:
1. Mapping & Discovery
- Inventory of connections between IT and OT
- Identification of potential attack vectors
- Backup and recovery procedure analysis
2. Isolated Simulations
- Tests on test environment or in isolated segments
- Propagation analysis without running real malware
- Security effectiveness verification
3. Recovery Testing
- Backup recovery testing
- Verification of time needed to restore systems
- Backup completeness check (PLC configurations, SCADA databases, etc.)
4. Documentation
- Detailed report with risk map
- Playbook - step by step what to do during attack
- Technical and organizational recommendations
Related Glossary Terms
Learn more about key concepts related to this service:
How we work
Our proven service delivery process.
Environment Analysis
Map dependencies between IT and OT
Attack Simulation
Controlled ransomware propagation tests
Backup Testing
Verify system recovery capability
Resilience Plan
Security improvement roadmap
Recovery Procedures
Documentation and team training
Benefits for your business
What you gain by choosing this service.
Minimize Downtime
Production runs even when IT is blocked
Avoid Losses
Every hour of downtime costs hundreds of thousands
NIS2 Compliance
Meet cyber risk management requirements
Board Peace of Mind
Know you're prepared for worst case
Related Articles
Expand your knowledge with our resources.
Firewall rule review: how to remove unused, overly permissive and duplicate rules
A firewall rule base grows with every project, and rarely does anything leave it. NIST recommends reviewing rules regularly, not only during an audit or an emergency. The review looks for unused, overly permissive and duplicate rules, but removes them carefully: zero hits in the last week does not always mean a rule is unnecessary.
Read more →External attack surface management (EASM): how to find forgotten domains, servers and services exposed to the internet
The external attack surface is everything an organisation exposes to the internet: domains, subdomains, IP addresses, open ports and services, including those set up without the IT department's knowledge. EASM discovers them from the attacker's perspective, and the value appears only when every asset found gets an owner and a decision.
Read more →Snapshot vs backup: why a storage array snapshot is not a backup and when it is enough
A storage array snapshot lets you roll a volume back to its state before a change within moments. According to NIST SP 800-209, however, it stores only the changed portions of data and is often unusable once the source data is lost. A snapshot therefore complements a backup but does not replace it.
Read more →Frequently Asked Questions
Common questions about OT/ICS Ransomware Resilience Testing.
Can the tests affect our production operations?
No, production safety is the priority. We conduct simulations on a test environment or in isolated network segments. We do not run real malware on the OT network - we analyze propagation and verify security measures without risk to production processes.
What does the OT system backup test include?
We verify backup completeness (PLC configurations, SCADA databases, HMI images), test actual system recovery, measure the time needed to restore production (RTO), and check whether the air-gap protects the backup copies.
How long do the tests take and what is the deliverable?
Tests take 5-10 business days. The deliverable is a report with a ransomware propagation risk map from IT to OT, network segmentation assessment, recovery test results, and a playbook with step-by-step procedures in case of an attack.
Do the tests help meet NIS2 requirements for critical infrastructure?
Yes, ransomware resilience tests directly address NIS2 requirements regarding cyber risk management, business continuity, and recovery capability after incidents. The report serves as documentation required by the regulator.